四己基溴化铵
tetrahexanaminium bromide
- 分子式:C24H52BrN
- 分子量:434.58
- CAS编号:4328-13-6
- 纯度:98%
基本信息
物性数据
参考谱图
安全信息
Code |
Hazard Statement |
Source |
H401 |
Toxic to aquatic life |
Expert Curated |
H335 |
May cause respiratory irritation |
European Chemical Agency (ECHA) Classification&Labelling Inventory - Notified classification and labelling - most common notifications, European Chemical Agency (ECHA) Classification&Labelling Inventory - Notified classification and labelling - most serious notifications, European Chemical Agency (ECHA) Classification&Labelling Inventory - Notified classification and labelling according to CLP criteria, Expert Curated |
H332 |
Harmful if inhaled |
European Chemical Agency (ECHA) Classification&Labelling Inventory - Notified classification and labelling - most serious notifications, European Chemical Agency (ECHA) Classification&Labelling Inventory - Notified classification and labelling according to CLP criteria |
H319 |
Causes serious eye irritation |
European Chemical Agency (ECHA) Classification&Labelling Inventory - Notified classification and labelling - most common notifications, European Chemical Agency (ECHA) Classification&Labelling Inventory - Notified classification and labelling - most serious notifications, European Chemical Agency (ECHA) Classification&Labelling Inventory - Notified classification and labelling according to CLP criteria, Expert Curated |
H315 |
Causes skin irritation |
European Chemical Agency (ECHA) Classification&Labelling Inventory - Notified classification and labelling - most common notifications, European Chemical Agency (ECHA) Classification&Labelling Inventory - Notified classification and labelling - most serious notifications, European Chemical Agency (ECHA) Classification&Labelling Inventory - Notified classification and labelling according to CLP criteria, Expert Curated |
H312 |
Harmful in contact with skin |
European Chemical Agency (ECHA) Classification&Labelling Inventory - Notified classification and labelling - most serious notifications, European Chemical Agency (ECHA) Classification&Labelling Inventory - Notified classification and labelling according to CLP criteria |
H302 |
Harmful if swallowed |
European Chemical Agency (ECHA) Classification&Labelling Inventory - Notified classification and labelling - most serious notifications, European Chemical Agency (ECHA) Classification&Labelling Inventory - Notified classification and labelling according to CLP criteria, Expert Curated |
Other Names and Identifiers
Canonical SMILES
[Br-].CCCCCC[N+](CCCCCC)(CCCCCC)CCCCCC
InChI
InChI=1S/C24H52N.BrH/c1-5-9-13-17-21-25(22-18-14-10-6-2,23-19-15-11-7-3)24-20-16-12-8-4;/h5-24H2,1-4H3;1H/q+1;/p-1
InChI Key
SYZCZDCAEVUSPM-UHFFFAOYSA-M
4 Other Names for this Substance
- 1-Hexanaminium, N,N,N-trihexyl-, bromide (9CI)
- Ammonium, tetrahexyl-, bromide (8CI)
- Tetrahexylammonium bromide (7CI)
- Tetra-n-hexylammonium bromide
参考文献
Experimental Properties
Electrical
Mechanical
Thermal
Experimental Spectra
1H-NMR
- (1) Denmark, Scott E.; Journal of the American Chemical Society, (2012), 134(32), 13415-13429, CAplus
- (2) Copyright Bio-Rad Laboratories. All Rights Reserved.
- (3) Avram, Liat; Organic Letters, (2003), 5(7), 1099-1102, CAplus
13C-NMR
- (1) Copyright Bio-Rad Laboratories. All Rights Reserved.
- (2) "Integrated Spectral Data Base System of Organic Compounds" data were obtained from the National Institute of Advanced Industrial Science and Technology (Japan)
IR
- (1) Sigma-Aldrich Co. LLC. (Spectral Data were obtained from John Wiley & Sons, Inc.)
- (2) Copyright Bio-Rad Laboratories. All Rights Reserved.
- (3) "Integrated Spectral Data Base System of Organic Compounds" data were obtained from the National Institute of Advanced Industrial Science and Technology (Japan)
- (4) Burnett, Andrew D.; Analytical Chemistry (Washington, DC, United States), (2013), 85(16), 7926-7934, CAplus
Mass
- (1) Spectral data were obtained from John Wiley & Sons, Inc.
- (2) "Integrated Spectral Data Base System of Organic Compounds" data were obtained from the National Institute of Advanced Industrial Science and Technology (Japan)
- (3) Dangi, Beni B.; Review of Scientific Instruments, (2010), 81(6), 063302/1-063302/10, CAplus
Raman
- (1) Sigma-Aldrich Co. LLC. (Spectral Data were obtained from John Wiley & Sons, Inc.)
- (2) Copyright Bio-Rad Laboratories. All Rights Reserved.