有机合成(108) 离子液体(441) 催化(166) 离子液体制备(12) 离子液体物性数据(10) 纳米(30) 分离过程(14) 综述(5) 电化学(57) 离子液体纯化(1) 气体处理(17) 荧光(4) 脱硫(1) 催化制氢(1) 太阳能电池(1) 离子液体性能研究(20) 变焦透镜(6) 纤维素溶解(6) 离子液体理论研究(4) 润滑(10) 添加剂(4) 溶剂(38) 气体压缩(1) 功能材料(42) 脱酸工艺(1) 产业化(30) 物化性质研究(2) 新能源(9) 新型离子液体(11) 会议(18) 分析检测(3) 电池(29) 空间技术(9) 高极性色谱柱(1) 离子液体市场分析(1) 电子技术(6) 生物相容性(9) 分析测试(16) 缩微实验室(1)
[Wiley数据库][2012]Application of NiMoO4 Nanorods for the Direct Electrochemistry and Electrocatalysis
发布时间:2016-03-15 21:56:33 阅读次数:
题名
|
[Wiley数据库][2012]Application of NiMoO4 Nanorods for the Direct electrochemistry and Electrocatalysis of Hemoglobin with Carbon ionic liquid Electrode
|
参考引用方式
|
Song Hu, Lili Cao, Zhaolan Sun, Jun Xiang, Ming Lu, Wei Sun. Electroanalysis 2012, 24, No. 2, 278–285
|
研究机构
|
华中科技大学;青岛科技大学
|
所涉及离子液体
|
|
研究领域
|
|
论文摘要
|
In this paper NiMoO4 nanorods were synthesized and used to accelerate the direct electron transfer of hemoglobin (Hb). By using an ionic liquid (IL) 1-butylpyridinium hexafluorophosphate (BPPF6) modified carbon paste electrode (CILE) as the basic electrode, NiMoO4 nanorods and Hb composite biomaterial was further cast on the surface of CILE and fixed by chitosan (CTS) to establish a modified electrode denoted as CTS/NiMoO4-Hb/CILE. UV-vis and FT-IR spectroscopic results showed that Hb in the film retained its native structures without any conformational changes. Electrochemical behaviors of Hb entrapped in the film were carefully investigated by cyclic voltammetry with a pair of well-defined and quasi-reversible redox voltammetric peaks appearing in phosphate buffer solution (PBS, pH 3.0), which was attributed to the direct electrochemistry of the electroactive center of Hb heme Fe(III)/Fe(II). The results were ascribed to the specific characteristic of NiMoO4 nanorods, which accelerated the direct electron transfer rate of Hb with the underlying CILE. The electrochemical parameters of Hb in the composite film were further carefully calculated with the results of the electron transfer number (n) as 1.08, the charge transfer coefficient (a) as 0.39 and the electron-transfer rate constant (ks) as 0.82 s-1. The Hb modified electrode showed good electrocatalytic ability toward the reduction of trichloroacetic acid (TCA) in the concentration range from 0.2 to 26.0 mmol/L with a detection limit of 0.072 mmol/L (3σ), and H2O2 in the concentration range from 0.1 to 426.0 mmol/L with a detection limit of 3.16×10-8 mol/L (3σ).
|
关键词
|
Hemoglobin, NiMoO4 nanorods, Ionic liquid, Carbon paste electrode, Electrochemistry
|